Is plug-in solar legal in the UK? The 800 W rules explained
The rules that let you plug a solar kit into a home socket took effect in Great Britain (England, Scotland and Wales) on 27 August 2026. Northern Ireland has not yet made plug-in use lawful. The table below takes each rule in turn, with the source it comes from. Last checked 5 October 2026.
Four documents make up the rules, and no single one of them makes plug-in solar lawful on its own. They are SI 2026/848 (a statutory instrument on plugs and network connection), the Plug-in Solar Device Interim Product Specification v2.0, Engineering Recommendation G98 Amendment 1 (network connection, approved by Ofgem) and, for planning in England, SI 2026/896.
The rules, one by one
| Item | What the rules say | Source |
|---|---|---|
| Watt limit | The inverter may be rated at most 800 W AC (and 800 VA and 3.5 A). The panels may add up to 2,000 W DC, with at most four panels and no more than two in series. Above 960 W of panels, the maker must advise you to consider a professional assessment of your wiring. "has a maximum rated alternating current output not exceeding 800 watts" , SI 2026/848, definition of "plug-in microgenerator" | |
| What counts | Solar only, no battery, connected by a standard plug, running in parallel with the grid. Plug-in batteries and solar-plus-battery kits are outside the rules. | |
| Equipment standard | The kit must meet the Plug-in Solar Device Interim Product Specification v2.0. The maker must type test it to the network rules (G98), list it on the Energy Networks Association Type Test Register before selling it, and mark it as compliant. There is no dedicated British Standard yet: the government calls the specification interim. | |
| Connection | A standard 13 A BS 1363 socket. The law does not require a dedicated circuit or an electrician. The plug is a non-rewireable moulded plug with a fuse of 5 A or less. Socket circuits only: not a lighting circuit and not a spur that feeds fixed equipment such as a cooker or boiler. No extension leads, multi-way, travel, RCD adaptors or plug convertors. An outdoor socket used for the kit must be IP55 or better. "we do not consider these requirements proportionate for this category of low-power product" , DESNZ government response, on mandatory inspections and dedicated circuits | |
| How many per home | One per household for now. The product specification would allow one per socket circuit, but the network rules (G98) take precedence and allow one per customer installation, effectively one per household. A block of flats counts each dwelling with its own consumer unit as a separate household. "Only one Plug-in Micro-generator is permitted in any given Customer Installation." , G98 Amendment 1, consultation draft, Appendix 1 A.1.2 | |
| RCD protection and consumer unit | Not a legal condition on the householder, but the kit's instructions must tell you to check that the installation has modern residual current protection (RCBOs) and is in good condition. If it has older fuses and no RCBOs, a professional electrician should check it and upgrade it where necessary. | |
| Telling your network operator | Required. You, not an installer, tell your distribution network operator when you plug in, using the plug-in form or the online route. The regulation says "before, or at the time of, commissioning"; a 2008 Health and Safety Executive exemption reproduced in the network rules allows no later than 28 days after. You tell them again when you remove the kit. No approval is needed before you connect. "the person installing the source of energy ensures that the distributor is advised of the intention to use the source of energy in parallel with the network before, or at the time of, commissioning the source." , ESQCR regulation 22(2)(c) | |
| Connection application or permit | None for a single kit under 16 A per phase. Plug-in kits are exempt from several installer-only network duties. A plug-in kit may sit alongside a wired rooftop system if the total stays within 16 A per phase; above that, the larger-system rules (G99) apply. | |
| Landlord, leasehold or managed building | No new right to install. Renters, leaseholders and residents of managed buildings must get any permission the landlord, freeholder or managing agent requires. Nothing in the rules overrides a lease or tenancy. "Users are responsible for obtaining any necessary permissions from the property owner, landlord, freeholder, managing agent or relevant authority prior to installation" , Product specification, clause 8.3.1 | |
| Buildings and fixings | Not allowed on aluminium or metal composite (ACM, MCM), high pressure laminate (HPL) or timber cladding, on timber balconies, or on buildings under external wall or building safety remediation. Must not be fixed to a party wall between dwellings. The fixing must be reversible and cannot rely on cable ties, rope, tape or straps alone. | |
| Planning permission (England) | Plug-in solar counts as solar PV for permitted development from 27 August 2026, with projection limits, and exclusions for listed buildings, wooden walls, balconies and fences, and some conservation area frontages. Scotland and Wales differ. | |
| Payment for exported power | No guaranteed payment for a self-installed kit. The Smart Export Guarantee asks for a certified installation and installer, and the government's own assessment says it is likely not to apply at first. | |
| Other conditions | The kit must come with a durable label to fix at or near your consumer unit, showing that a plug-in solar device is on the wiring. Panels must come off the maker's mounting without a professional tool. You are responsible for checking your insurance. The instructions must carry a prominent warning that the kit is not meant to be used with a battery. |
What this page does not tell you
It states the rules and their sources. It cannot tell you that a set-up is safe or lawful: that depends on your wiring, socket, lease and area. The product specification itself tells users to ask a professional electrician when unsure.
Not yet confirmed: the final network-connection text (G98 Amendment 1) was not available online on the date checked, so the notification form names come from the June consultation draft (how to notify your network operator). Ofgem says later changes were limited to clarifications, simpler customer forms, implementation arrangements and minor edits.
Check your own kit against the limits · What to check before you buy · Dated log of rule re-checks
Sources
- The Plugs and Sockets etc. (Safety) Regulations 1994 and Electricity Safety, Quality and Continuity Regulations 2002 (Amendment) Regulations 2026, SI 2026/848, legislation.gov.uk.
- Plug-in Solar Device Interim Product Specification, version 2.0 (July 2026), Department for Energy Security and Net Zero.
- Electricity Safety, Quality and Continuity Regulations 2002, regulation 22, legislation.gov.uk.
- Plug-in solar: government response (July 2026), Department for Energy Security and Net Zero.
- Ofgem decision to approve DCRP/MP/26/02, proposed amendment to facilitate plug-in microgeneration (11 August 2026), Ofgem.
- Engineering Recommendation G98 Issue 2 Amendment 1, consultation draft (June 2026), Energy Networks Association, via dcode.org.uk. The final text was not found online on the checked date. Form names and wording come from the June draft; Ofgem says later changes were limited to clarifications, simpler customer forms, implementation arrangements and minor edits.
- Households can save as plug-in solar panels come to market (26 August 2026), GOV.UK.
- The Town and Country Planning (General Permitted Development) (England) (Amendment) Order 2026, SI 2026/896, legislation.gov.uk.
- Smart Export Guarantee (SEG) for generators; quotes from Ofgem's "SEG: Guidance for Generators" (December 2019), Ofgem. The quotes on this site come from Ofgem's "SEG: Guidance for Generators" (December 2019). No newer plug-in-specific Ofgem statement was found.
- Plug-in solar: final stage impact assessment (DESNZ024(F)-26-CP30), Department for Energy Security and Net Zero.
Last updated .