How the plug-in solar numbers are calculated
Every figure on this site comes from one of two places: the rules, which each page cites to their primary sources, or the production calculation described here.
Production data
Output comes from PVGIS 5.3 seriescalc (hourly), European Commission Joint Research Centre: radiation data PVGIS-SARAH3, weather data ERA5, hourly values for 2005 to 2023, for 15 UK city-centre points, five directions (south, south-east, south-west, east, west) and two mountings (vertical at 90 degrees and tilted at 35 degrees). The data were fetched on 2 October 2026. PVGIS states that "the information provided by PVGIS is free and there are no restrictions on its use". The European Commission does not endorse this site.
The calculation
- For one city, direction and mounting, PVGIS gives the hourly power of a 1 kWp array for 19 years, with 14% system losses. That is the loss figure PVGIS suggests by default, and a microinverter kit may differ. PVGIS is run with its free-standing mounting setting. The results for each city are on output by UK city.
- For each month we add the hourly power across all years and divide by 19. We do this unclipped and with the power capped at each of 19 levels from 0.10 to 1.00 kW of inverter per kWp of panels.
- Your inverter rating divided by your panel watts picks the cap level. We read the monthly figures at that level, interpolating linearly between levels, and multiply by your panel kilowatts. So a bigger array on the same inverter loses its midday peak, as a real kit does.
- Value in pounds is output in kWh, times your rate in pence divided by 100, times the share of the output you use at home.
Nothing is rounded inside the calculation. Figures are rounded half-up to two decimals at the moment they are shown.
What the numbers leave out
- Shading from buildings and trees beyond the horizon PVGIS models, balcony overhangs and neighbouring walls.
- A different year: monthly output varies from year to year, and the figures are 19-year averages.
- Inverter efficiency at low power, panel ageing and soiling beyond the 14% loss figure.
- The exact spot: figures are for one point in the city centre, so a site elsewhere in the city can differ.
- How much you use: money counts only the share of output used at home. Exported power earns nothing by default (why).
Electricity rate
The default rate is 26.32p per kWh, the Ofgem energy price cap electricity unit rate for 1 October to 31 December 2026, an average for Direct Debit in England, Scotland and Wales. It does not cover Northern Ireland, and the cap differs by region and payment method. Treat it as an example and type the rate on your own bill.
The rule check
The check compares your inverter's AC rating with 800 W, your panels' total with 2,000 W, the panel count with 4 and the panels in series with 2. These come from SI 2026/848 and the Plug-in Solar Device Interim Product Specification v2.0 ( the UK rules in full ). The check does not read your wiring, which no website can do. The socket and circuit checklist is information from the specification, not a pass or fail.
Test vectors
The calculation is checked against these known pairs on every build.
| Input | Expected output |
|---|---|
| Inverter 800 W AC, four 400 W panels, two in series | Within the rules |
| Inverter 1,000 W AC | Over the 800 W AC limit by 200 W |
| Inverter 800 W AC, five 450 W panels | Over the panel rules: 2,250 W DC exceeds 2,000 W, and 5 panels exceeds 4 |
| 97.20 kWh at £0.25 per kWh | £24.30 |
Sources
- PVGIS usage conditions and data protection, European Commission Joint Research Centre.
- PVGIS 5.3 API, non-interactive service, European Commission Joint Research Centre.
- The Plugs and Sockets etc. (Safety) Regulations 1994 and Electricity Safety, Quality and Continuity Regulations 2002 (Amendment) Regulations 2026, SI 2026/848, legislation.gov.uk.
- Plug-in Solar Device Interim Product Specification, version 2.0 (July 2026), Department for Energy Security and Net Zero.
- Energy price cap unit rates and standing charges, 1 October to 31 December 2026 (electricity 26.32p per kWh, average for Direct Debit in England, Scotland and Wales), Ofgem.
Last updated .