How the US plug-in solar numbers are calculated
Every figure on the US pages comes from one of three places: the state laws, each cited to its statute on the state's page; electricity prices from the U.S. Energy Information Administration; and the output calculation below. This page sets out the data, the formula, what the numbers leave out and the cases the tests check.
Production data
Output comes from PVGIS 5.2 seriescalc (hourly), European Commission Joint Research Centre: radiation data from PVGIS-NSRDB (NREL National Solar Radiation Database (satellite derived), served by PVGIS), hourly values for 2005 to 2015, for 21 US cities (one point near the center of each), five directions and two mountings (vertical at 90 degrees and tilted at 35 degrees). The data were fetched on October 2, 2026. Every output figure is a long-term average of those 11 years: it describes a typical past year, not a forecast, and no year after 2015 is in it. PVGIS states that "the information provided by PVGIS is free and there are no restrictions on its use". The European Commission does not endorse this site.
The calculation
- For one city, direction and mounting, PVGIS gives the hourly power of a 1 kWp array for each year, with 14% system losses. PVGIS is run with its free-standing mounting setting. The results for each city are on output by US city.
- For each month we add the hourly power across all years and divide by the number of years. We do this unclipped and with the power capped at each of 19 levels from 0.10 to 1.00 kW of inverter per kWp of panels.
- Your inverter rating divided by your panel watts picks the cap level. We read the monthly figures at that level, interpolating linearly between levels, and multiply by your panel kilowatts.
- Value in dollars is output in kWh, times your rate in cents divided by 100, times the share of the output you use at home.
Nothing is rounded inside the calculation. Figures are rounded half-up to two decimals at the moment they are shown.
What the numbers leave out
- Shading from buildings, trees, the railing and the balcony above, which matters most for balcony mounting.
- Your exact spot: figures are for one point near the center of each city.
- Year-to-year swings: any single month can come in above or below its long-term average.
- The hourly data use UTC timestamps, so a few evening hours at each month boundary can fall in the neighboring month. The effect on monthly totals is small.
- Inverter efficiency at low power, panel aging and dirt beyond the 14% loss figure.
- How much you use at home: the dollar value counts only the share you enter.
Electricity rate
The default rate is the average residential price in the city's state, year-to-date through August 2026, from the Energy Information Administration (for example 18.19 cents per kWh for the United States as a whole). It is an average across utilities and plans, so it is not your rate: type the rate on your own bill.
The rule check
The check compares your inverter's AC rating with the limit in your state's law ( watt limits by state ). Where a law does not say whether its watt limit is AC or DC, the check still uses the AC rating, and the state page says so. No website can read your wiring. The outlet and circuit checklist is information, not a pass or fail.
Test vectors
The automated tests that run on every build cover these cases.
| Input | Expected output |
|---|---|
| Inverter 800 W AC in Utah (limit 1,200 W) | Within the limit by 400 W |
| Inverter 1,500 W AC in Utah | Over the 1,200 W limit by 300 W |
| Inverter 800 W AC in Maine | Above the 420 W plug-in-yourself tier, within the 1,200 W tier that needs a licensed electrician |
| 100 kWh at 20 cents per kWh, 50% used at home | $10.00 |
Sources
- PVGIS usage conditions and data protection, European Commission Joint Research Centre.
- PVGIS API, non-interactive service (version 5.2 with the NSRDB radiation database, used for US cities), European Commission Joint Research Centre.
- Electric Power Monthly, Table 5.6.B: average price of electricity to ultimate customers by end-use sector, by state, year-to-date through August 2026, U.S. Energy Information Administration.
Last updated .